A dew point transmitter measures the moisture content of a gas by continuously monitoring the temperature at which water vapour begins to condense — critical for compressed air, process gas and hazardous-area applications where excess moisture causes corrosion, freezing, contamination or product quality failures. IJ Instruments supplies dew point transmitters covering -110°C to +20°C dew point, with intrinsically safe versions for hazardous areas and a range of process connections to suit new and retrofit installations.

📏 -110°C to +20°C dp Range±2°C AccuracyATEX / IECEx Available
💧 Dew Point or ppmV Output 🔌 2-Wire, 4–20mA Loop Powered 🏭 Compressed Air, Gas & Hazardous Areas 📞 +91 99592 44911

Understanding Dew Point Measurement

What Is a Dew Point Transmitter?

Dew point is the temperature at which air or gas becomes saturated with water vapour and condensation begins to form. A dew point transmitter measures this continuously and outputs a proportional 4–20mA signal, letting you monitor gas dryness in real time rather than relying on periodic spot checks.

01

Ceramic Metal-Oxide Sensing

A ceramic metal-oxide sensor changes its electrical impedance as moisture is absorbed and released, giving a stable, repeatable measurement that holds calibration over the sensor's working life — more robust than capacitive polymer sensors in dirty or high-pressure gas streams.

02

Why Dew Point Matters

Moisture in compressed air or process gas causes pipe corrosion, freezing in cold lines, contamination of pneumatic instruments, and quality failures in moisture-sensitive processes — continuous dew point monitoring catches dryer failures before they become production problems.

03

Dew Point vs. ppmV Output

The same transmitter can output dew point temperature (°Cdp) or moisture content (ppmV) — useful when your process specification is written in parts-per-million rather than temperature terms.

Product Range

Dew Point Transmitter Models

Three connection variants of the Easidew dew-point transmitter range from Michell Instruments — sharing the same sensing technology and performance, differing in process and electrical connection to suit your installation.

💧
EA2-TX Series
Dew Point Transmitter

Easidew — 5/8" UNF Process Connection

The standard Easidew transmitter with 5/8" UNF process connection and MiniDIN 43650 electrical connector — a rugged, impedance-based dew point transmitter for continuous measurement in compressed air or process gas.

5/8" UNFMiniDIN 43650Intrinsically Safe Option
Range-110°C to +20°C dp
Output4–20mA, 2-Wire
Accuracy±2°C dp
Get Technical Consultation →
🔩
EA34-TX Series
Dew Point Transmitter

Easidew 34 — 3/4" UNF Process Connection

Same Easidew sensing performance in a 3/4" UNF process connection variant — a direct fit for installations standardized on 3/4" UNF ports or where a larger thread engagement is preferred.

3/4" UNFMiniDIN 43650Intrinsically Safe Option
Range-110°C to +20°C dp
Output4–20mA, 2-Wire
Accuracy±2°C dp
Get Technical Consultation →
🔗
EA2-TX-M12 Series
Dew Point Transmitter

Easidew M12 — Modbus RTU Option

M12 5-pin electrical connector variant with a choice of G1/2" BSP, 3/4" UNF or 5/8" UNF process connection. Selecting the M12 5-pin connector also enables Modbus RTU over RS485 output alongside 4–20mA.

M12 ConnectorModbus RTU / RS4853 Connection Options
Range-110°C to +20°C dp
Output4–20mA or Modbus RTU
ProtectionIP65
Get Technical Consultation →

Technical Specifications

The Easidew transmitter range is manufactured by Michell Instruments (part of the Process Sensing Technologies group) using ceramic metal-oxide moisture sensing technology, with high-volume manufacturing and calibration traceable to NPL and NIST ISO 17025 standards. IJ Instruments is a dealer and reliable sourcing partner for dew point transmitters in Tamil Nadu and pan India — share your gas type, pressure and installation details for a free technical consultation before you order.

Key Specifications

Measurement Range-110°C to +20°C dp
Accuracy±2°C dp (over compensated range)
Repeatability0.5°C dp
Response Time5 min to T95 (dry to wet)
Operating PressureUp to 525 barg
Supply Voltage12–28 VDC
Operating Temp.-40°C to +60°C
ATEX IECEx cQPSus UKCA UL CRN

Electrical

Output Signal4–20mA (2-wire, current source)
M12 VariantModbus RTU over RS485
Analog Scaled RangeDew point or 0–3000 ppmV
Load ResistanceMax. 250Ω @ 14V (500Ω @ 24V)
Current Consumption23mA max.

Mechanical

Housing Material316 Stainless Steel
Ingress ProtectionIP66 (IP65 for M12 variant)
Filter (Sensor Protection)HDPE <10µm std. / SS Sintered <80µm optional
Weight~150g
Oxygen ServiceOptional Cleaning Available

Intrinsically Safe Area Certificates

ATEX/UKCAII 1 G Ex ia IIC T4 Ga
IECExEx ia IIC T4 Ga
cQPSusClass I, Div 1, Groups A-D, T4
Ambient Range (Ex)-20°C to +70°C

Where It's Used

Dew Point Transmitter Applications

💨

Compressed Air Dryers

One stocked model covers Class 1 to Class 6 industrial compressed air dryer applications.

🫁

Breathing Air

Moisture monitoring for breathing air systems where dryness is a safety requirement.

❄️

Hydrogen Coolant

Dew point monitoring in generator hydrogen cooling systems.

🧪

Inert & Bulk Gases

Moisture measurement in nitrogen, argon and other inert gas supply lines.

📦

Glove Boxes

KF40 flange option for direct mounting on glove box moisture monitoring points.

🔥

Welding Gases

Ensuring shielding gas dryness for weld quality control.

⚠️

Hazardous Areas

Intrinsically safe (I.S.) versions with ATEX, IECEx and cQPSus certification.

🅾️

Oxygen Purity

Optional oxygen-service cleaning for enriched oxygen applications.

Low Cost of Ownership

Sensor Exchange & Recalibration Program

Keep your process running with minimal downtime for calibration and maintenance.

🔄 Sensor Exchange

Order a guaranteed, reconditioned sensor. When it arrives, exchange it for your installed unit and return the old one — resulting in zero process downtime while your original sensor is serviced.

🎯 Recalibration

Return your installed sensor for inspection, checking and re-calibration with a traceable 13-point calibration certificate, then have it returned — maintaining ongoing measurement traceability.

Why IJ Instruments

Your Reliable Source for Dew Point Transmitters in India

🎯 Free Technical Consultation

Share your gas type, pressure, process connection and hazardous-area requirement — we'll help you select the right model and options.

🤝 Reliable Sourcing Partner

We help you access genuine dew point transmitters in India without the hassle of sourcing directly from overseas.

📋 Documentation Support

Datasheets, order codes and calibration certificates to support your engineering and procurement process.

🚚 Pan India Delivery

Coordinated sourcing and delivery to industrial plants, OEMs and system integrators across India.

Not sure which dew point transmitter fits your application?

Share your gas type, pressure, process connection and whether you need a hazardous-area certified version — our team will recommend the right model.

Request Technical Consultation →

FAQs

Dew Point Transmitters — Frequently Asked Questions

What is dew point and why does it matter for compressed air?

Dew point is the temperature at which water vapour in the air begins to condense. In compressed air systems, a high dew point means more moisture is present, which can cause pipe corrosion, freezing in cold lines, and damage to pneumatic instruments and valves — continuous dew point monitoring lets you catch dryer failures before they cause downstream problems.

What's the difference between dew point output and ppmV output?

Both describe the same moisture content, just in different units — dew point in °C or °F, and ppmV as parts-per-million by volume. The same transmitter can be configured to output either, useful when your process specification is written in one unit but your control system expects the other.

Do I need an intrinsically safe (I.S.) version?

If the transmitter will be installed in a classified hazardous area (Zone 0/1 or Class I Division 1, for example around flammable gas processing), you'll need an I.S. certified version with ATEX, IECEx or cQPSus approval as applicable to your region — tell us your area classification and we'll confirm the right certification.

Which process connection should I choose?

It depends on your existing piping and sample system — 5/8" UNF and 3/4" UNF are common threaded options, while the M12 variant additionally offers G1/2" BSP and adds a Modbus RTU communication option. Share your installation details for a recommendation.